296 KAYENNE — User Manual
Section 3 — System Operation
2. Press the Source eDPM button (Figure 199), K1-K4 buttons of the top row
are now assigned as e-DPM channels Ch1-Ch4 (the button legends
remain
K1-K4).
3. Select a Source e-DPM channel.
4. Select the Destination eDPM button (K1-K4 destination button LED labels
change to
Ch1-Ch4).
5. Select a Destination e-DPM channel.
6. Press the Copy button (below the joystick).
To Swap e-DPM Channels:
e-DPM Channels can swapped with Keyers and vice versa.
1. From the Home mode in the Multi-Function Module, press the Swap
button.
2. Press the Source eDPM button (Figure 199), K1-K4 buttons of the top row
are now assigned as e-DPM channels Ch1-Ch4, however the button
legends remain
K1-K4.
3. Select a Source e-DPM channel.
4. Press the Destination eDPM button, K1-K4 destination button LED labels
change to
Ch1-Ch4.
5. Select a Destination e-DPM channel.
6. Press the Swap button (below the joystick).
Undo Button
The Undo button (below the joystick) reverses a copy or swap operation that
has been performed. Only one level of undo is supported. For example,
pressing
Undo a second times does not return the MEs to their previous
states before the first Undo was performed.