MFG-2000 Series User Manual 
116 
 
When a signal of large amplitude is input to a amplifier, the main 
parameters which determine the performance of the amplifier are 
frequency response and its thermal conditions. When the frequency 
of a input signal of large amplitude increases, the operating current 
and power consumption of the amplifier will increase with the 
increases of input signal even the amplifier is without load, and 
signal distortion will increase with the frequency's increase as well. 
And results in amplifier becoming hot, performance degradating. 
Therefore, it is necessary made some restrictions on the frequency 
and amplitude of inputing signals.