OPERATION
219
3. Use the Selector knob to move
the cursor down to Go_NoGo
Tone (below the initial screen).
4. Press the Selector knob to
highlight Go_NoGo Tone, then
turn to change to ON/OFF.
Go_NoGo Tone OFF
5. Press the Selector Knob or Enter
to confirm selection.
OR
ENTER
Adjusting Slave Knob Settings
Channel loads can be edited using the local load
module or the Mainframe. When using the slave
knob to edit a load, the load module display can
be set to two different types: SetValue and
Measured.
When a load is ON, SetValue will always display
the set value (A Value, B Value) on the local load
module display whilst “Measure” will show the
actual measured value when editing the load.
These settings apply to all channels.
The “Measure” setting can be temporarily
disabled by pressing the Slave Knob to display the
“SetValue” instead of the “Measure” value in the
local load module display.
Slave Knob
Measure/SetValue
1. Press the Shift Key then the Help
key to access the Utility menu.
UTILITY
HELP
SHIFT