OPERATION
187
Adjusting the Von Voltage and Latch
Background
The Von Voltage is the voltage point at which the
load module will start to sink current. When Von
latch is set to ON, the load will continue to sink
current after being tripped, even if the voltage
drops below the Von Voltage level. The step
resolution of Von Voltage is load module
dependent.
Parameters
Von Voltage
0.0~Rating volts
Von Latch
ON/OFF
Panel operation
Ensure the menu is in the configuration menu. See
page 180.
Configure
Previous
Menu
Protection
Go-NoGoOther Group
1. Press the F2 (Other) key to
enter the Other menu.
F2
Configure
Previous
Menu
Protection
Go-NoGo
CH1
Other
Von Voltage
Von Latch
CH CONT
Independent
CC Vrange
V
0.00
OFF
Panel
OFF
High
conf
Group
CCDH
80V
LOAD
USB
06/15/18
16 : 50
Load D-Time 0.0 S
2. Use the Selector knob to
highlight Von Voltage.