PEL-2000A Series User Manual
276
Recall Factory/Users Defaults
The Factory/Users defaults can be saved or
recalled at any time. For details on the factory
defaults please see the default settings in the
appendix, page 302
1. Press the File key.
FILE
2. Press F1 repeatedly until the
Media Default menu appears.
Media
Memory
Media
USB
Media
Default
F1
Configure
Recall
CH2
Media
Default
Load Default Setup
CCH
file
500V
LOAD
USB
Save
Factory
Default
06/15/18
16 : 50
3. Press Factory Default (F2) to recall
the factory default settings.
F2