OPERATING DESCRIPTION
77
Sequence
The Sequence function is used to create high
resolution load simulations. Each Sequence can be
configured to create a unique load profile to
accurately simulate loads in real time. Sequences
are only applicable for CC (Static) and CR (Static)
modes.
Note: Sequences are not to be confused with the
sequences used to create a program. They are not the
same and cannot be used interchangeably.
Sequences (SEQ memory) cannot be used in
Programs and Programs cannot load Sequences.
The Sequence function is able to simulate a load to
a high resolution. Each channel is able to change
its load sink within 25us ~ 60000s per point
independently. When used in parallel, multiple
loads can be set concurrently to simulate the loads
placed on multiple output power sources.
The diagram below shows the load profile of a
DUT at start-up.