PEL-2000A Series User Manual
84
Configurations Description
There are a number of different configurations for the PEL-2000A
series including protection modes, operating configurations, and
file system configurations. The Configuration Description section
describes what the different configurations are used for and how
they can be relevant to different operations.
Protection Modes
The PEL-2000A series include a number of
protection modes: Over Current Protection, Over
Voltage Protection, Over Power Protection, Under
voltage protection and Constant Power Protection.
The protection modes are useful to protect both the
load modules and the DUT(s). A buzzer can be set
to notify when a protection setting has been
tripped. When a protection feature is activated
and has been tripped then the load unit will
display an alarm. The Mainframe will also display
an alarm. When an alarm has been tripped the load
will stop sinking current/voltage. There are three
Over load protection settings: ON, OFF and Clear.