OPERATING DESCRIPTION
83
Parallel Dynamic Loading
Background
The PEL-2000A series of DC electronic loads
support parallel dynamic loading. This simply
means that when the load modules of a
mainframe are connected in parallel and set to
dynamic mode, they can perform dynamic tests
synchronously following the same clock. Under
dynamic mode, load current or resistance is
pulsed between two preset levels. When used in
parallel, higher powered outputs can be tested.
This ability gives the PEL-2000A series the
flexibility to perform dynamic tests over a wide
range of power outputs.
For connection details see the Parallel Load
Connections section on page 53.
The diagram below shows how two load modules
are able to sink a higher load when used in
parallel under dynamic mode.
Total load
Load 2
Load 1
Note
The same type of load modules must be used
operated in parallel.