PEL-2000A Series User Manual
144
Select CV Range
Constant Voltage mode can run in high and low
range. Range is dependent on the load module.
Ensure the menu is in CV Mode. See page 144.
ConfigureConfigure
Mode
CP
Range
Low
1. Press the F2 (Range) key
repeatedly until High or Low
range is selected.
F2
Range
High
Range
Low
The range will be reflected in both the
bottom menu system and the Current
Operation Channel Status panel.
CVL
CH1
CV High Range
CV Low Range
CVH
CVL
Note
Changing the range will only affect the current
(active) channel. Other channels will not be affected
by any changes.
Select CV Response Speed
Constant voltage mode has fast and slow response
speeds. Quick current changes can induce line
voltage, making it more difficult for the PEL-
2000A series load to maintain a constant current.
In these types of conditions, slow response speed
is recommended.
Maximum current range is dependent on the load
module type.