EasyManua.ls Logo

GW Instek PEL-2000A Series - Configure Channel Control Interface

GW Instek PEL-2000A Series
324 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PEL-2000A Series User Manual
284
Configure Channel Control interface
Connector
Screwless connector.
Wire Gauge
22-28 AWG (24 AWG
recommended).
Wire connection
10 mm strip gauge for
connection.
10.0 mm
Input
0-10V.
1 6
GND
Negative potential of the load input
terminal.
I MON
(OUTPUT)
Load input current monitor; where
0V = 0% of input current and 10V =
100% of input current.
V MON
(OUTPUT)
Load input voltage monitor; where
0V = 0% of input voltage and 10V =
100% of input voltage.
Ext Voltage ref
(INPUT)
External voltage reference; Where
0V=0% of rating voltage/current
and 10V = 100% of rating
voltage/current. The external
voltage reference is for CC and CV
mode.

Table of Contents

Related product manuals