INTERFACE
285
Load On
Load On Input.
Load on = Active low.
Load off = Active high. (Pin 5 of the
connector is internally pulled up to
3.3V with a 10kΩ resistor when the
switch is open. Thus when the
switch is open, pin 5 is logically
high. When the switch is closed, pin
5 is pulled down to the GND
ground level, making pin 5 logically
low)
Switch
Channel
Control
1
5
+3.3V
GND
10k
The Load On/Off determines
whether the external switch is closed
(low) or open (high)
High
Low
Load
On
Off
Load on
Load off
Channel Control
+15V
Internal power output. Max 50mA.