D1-N Series Servo Drive User Manual Tuning
6-54 HIWIN MIKROSYSTEM Corp.
Effective Range
-100
mm
-50
mm
100
mm
100
mm
-100
mm
-100
mm
6.10 Compensation function for resolver signal
The absolute accuracy of a resolver could be influenced by the quality of its signal. If its signal is properly
compensated, the absolute accuracy can be enhanced. The compensation table for resolver signal is set
for users and only needs to be reset when the servo drive or motor is changed.
Note:
The signal compensation function is only available in servo drive which supports resolver signal.
Servo drive coordinates = 100
Servo drive coordinates = 0
= Start position
= 100
Servo drive coordinates = -100
coordinates =
0
= Start position
= -100
Servo drive coordinates = 100
coordinates