7 Configuration
166
7.18.7 Time operation
A time frame is defined for time operation (max. 24 hours); during this period, a specific memory value
and a specific memory cycle are active.
Time operation has higher priority compared with standard operation, but lower priority than event oper-
ation.
Device dialog box
Parameter
Parameter Selection/settings Description
Start 00:00:00 Time at which to start time operation.
Start = End: Time operation is inactive.
End 00:00:00 Time at which to end time operation
again.
Start = End: Time operation is inactive.
Memory values See "Standard operation". See "Standard operation".
Memory cycle 0 s ... 1s... 32000 s See "Standard operation".