249
9 Configuration – in setup program only
9.12.16 Text selection from list
Setup dialog box
Parameter
Parameter Selection/settings Description
Text destination Text variable into which the text selected in the process screen is written.
No selection No variable selected.
Select variable. Selector
Index destination Analog variable into which the index (position in the list area, beginning with 0) of
the selected text is written.
No selection No variable selected.
Select variable. Selector
First text 1 to ... First selectable text (text number) in the
text list
Number of texts 1 to 50 (10) Number of selectable texts in the text list
(as of the first selectable text)
Number of char-
acters
1 to 160 (100) Maximum number of characters in the
event of a modifiable text
Text editable Yes ( ), No ( ) If "Yes" is selected, the selected text can
be edited (index destination is then dis-
abled).