Action
On a regular basis:
•
Check the LEDs on PIC faceplates. The meaning of the LED states differs for various PICs. For more
information, see the MX Series Interface Module Reference. If the FPC that houses the PIC detects a PIC
failure, the FPC generates an alarm message to be sent to the Routing Engine.
•
Issue the CLI show chassis fpc pic-status command. The PIC slots in an FPC are numbered from 0 through
1, top to bottom:
user@host> show chassis fpc pic-status
Slot 0 Online DPC 40x 1GE R
PIC 0 Online 10x 1GE(LAN)
PIC 1 Online 10x 1GE(LAN)
PIC 2 Online 10x 1GE(LAN)
PIC 3 Online 10x 1GE(LAN)
Slot 1 Online MX FPC Type 3
PIC 0 Online 1x OC-192 SONET
PIC 1 Online 1x OC-192 SONET
For further description of the output from the command, see the CLI Explorer.
RELATED DOCUMENTATION
MX960 PIC Description | 78
Replacing an MX960 PIC | 517
Troubleshooting the MX960 PICs | 662
MX960 PIC Serial Number Label | 690
Maintaining Cables That Connect to MX960 DPCs, MPCs, MICs, or PICs
Purpose
For optimum router performance, verify the condition of the cables that connect to the DPCs, MPCs,
MICs, or PICs.
Action