Table 79: Router Environmental Specifications (continued)
ValueDescription
Normal operation ensured in relative humidity range of 5% to
90%, noncondensing
Relative humidity
Normal operation ensured in temperature range of 32°F (0°C)
to 104°F (40°C)
Nonoperating storage temperature in shipping container:
–40°F (–40°C) to 158°F (70°C)
Temperature
Designed to meet Telcordia Technologies Zone 4 earthquake
requirements
Seismic
AC power: 27,007 BTU/hour (7920 W)
DC power: 18,987 BTU/hour (5568 W)
Maximum thermal output
NOTE: Install the router only in restricted areas, such as dedicated equipment rooms and
equipment closets, in accordance with Articles 110-16, 110-17, and 110-18 of the National
Electrical Code, ANSI/NFPA 70.
RELATED DOCUMENTATION
Tools and Parts Required to Maintain the MX960 Router | 591
Definition of Safety Warning Levels
MX960 Site Preparation Checklist
The checklist in Table 80 on page 182 summarizes the tasks you must perform when preparing a site for
router installation.
181