Immunity
•
EN 55024 +A1+A2 Information Technology Equipment Immunity Characteristics
•
EN-61000-3-2 Power Line Harmonics
•
EN-61000-3-3 +A1 +A2 +A3 Power Line Voltage Fluctuations and Flicker
•
EN-61000-4-2 +A1 +A2 Electrostatic Discharge
•
EN-61000-4-3 +A1+A2 Radiated Immunity
•
EN-61000-4-4 Electrical Fast Transients
•
EN-61000-4-5 Surge
•
EN-61000-4-6 Immunity to Conducted Disturbances
•
EN-61000-4-11 Voltage Dips and Sags
The router is designed to comply with the following standards:
•
NEBS
•
GR-1089-Core: EMC and Electrical Safety for Network Telecommunications Equipment
•
SR-3580 NEBS Criteria Levels (Level 3 Compliance)
•
GR-63-Core: NEBS, Physical Protection
RELATED DOCUMENTATION
Compliance Statements for NEBS for the MX960 Router | 752
Compliance Statements for EMC Requirements for the MX960 Router | 753
Compliance Statements for Environmental Requirements | 754
Compliance Statements for Acoustic Noise for the MX960 Router | 755
Compliance Statements for NEBS for the MX960 Router
•
The equipment is suitable for installation as part of the Common Bonding Network (CBN).
•
The equipment is suitable for installation in locations where the National Electrical Code (NEC) applies.
•
The battery return connection is to be treated as an isolated DC return (that is, DC-I), as defined in
GR-1089-CORE.
•
You must provision a readily accessible device outside of the equipment to disconnect power. The device
must also be rated based on local electrical code practice.