Troubleshooting the MX960 PICs
Problem
Description: The PICs are not functioning normally.
Solution
Check the status of each port on a PIC by looking at the LED located on the PIC faceplate. For information
about the meaning of LED states on different PICs, see the MX Series Interface Module Reference.
Check the status of a PIC by issuing the show chassis fpc pic-status CLI command. The PIC slots in the
FPC are numbered from 0 through 1, top to bottom:
user@host> show chassis fpc pic-status
Slot 0 Online DPC 40x 1GE R
PIC 0 Online 10x 1GE(LAN)
PIC 1 Online 10x 1GE(LAN)
PIC 2 Online 10x 1GE(LAN)
PIC 3 Online 10x 1GE(LAN)
Slot 1 Online MX FPC Type 3
PIC 0 Online 1x OC-192 SONET
PIC 1 Online 1x OC-192 SONET
For further description of the output from the command, see the CLI Explorer.
RELATED DOCUMENTATION
MX960 PIC Description | 78
Replacing an MX960 PIC | 517
Maintaining MX960 PICs | 616
MX960 PIC Serial Number Label | 690
Troubleshooting the MX960 MICs
Problem
Description: The MICs are not functioning normally.
Solution
662