Figure 240: Rear View of a Fully Configured AC-powered High-Capacity Second-Generation Powered
MX960 Router Chassis
4—1— Power supply ejectorsAir exhaust
5—2— Grounding pointsPower distribution unit cover
6—3— ESD pointHigh-capacity second-generation AC power supplies
If necessary, pull the spring-loaded locking pin in the release lever away from the chassis and turn the
release lever counterclockwise until it stops. Let go of the locking pin in the release lever. Ensure that
the pin is seated inside the corresponding hole in the chassis.
3. On the power supply, rotate the metal cover away from the input mode switch to expose the switch.
4. Move the input mode switch to position 0 for one feed or position 1 for two feeds (see
Figure 115 on page 339).
642