7-3
Version 1.73 Copyright © 1997 Link Communications Inc. 1/18/97
024: Set Up RS-232 Serial Baud Rate
This command allows you to set up the baud rate for the RLC-Club's main serial port. The
baud rate for the main serial port should be set to match the computer, serial terminal, or
modem that you have connected to it to program the controller with.
<024> x..x
Parameters:
- 024 is the default command name.
- x..x is the actual baud rate. Any baud rate from 300-19200 including non-standard
rates can be specified. The baud rate you enter will be rounded slightly to
the nearest available rate, but should always be compatible with the actual
rate selected. The standard baud rates supported are 300, 600, 1200,
2400, 4800, 9600 and 19200 baud.
Default:
9600 Baud rate selected
Example:
Want to set the baud rate to 2400 baud
<024> 2400 unkey, 'D' or <Enter>