13-14
Version 1.73 Copyright © 1997 Link Communications Inc. 1/18/97
124: Set Autodial Slot
This command allows you to set one of the autodial slots. For a description of the autodial slots
and how to use them, see the autopatch section before Command 110.
<124> sss d..d
Parameters:
- 124 is the default command name.
- SSS is the slot number (000..500)
- D..D is the whole number to be dialed (up to 18 digits), not including any predial digits
(they must be set with Command 115 - you can keep them from being
sent for an autodial slot with Command 126).
Notes:
• You can clear the data out of a slot by entering Command 124 SSS D or unkey
• You can disable a slot without erasing it with Command 127.
• After you program an autodial memory, the predial information for that slot is enabled
• Autodial numbers are not checked by the long distance dialing tables
125: Recall Autodial Slot
This command allows you to recall the contents of one of the autodial slots.
<125> sss
Parameters:
- 125 is the default command name.
- SSS is the slot number (000..500)

Table of Contents