20-2
Version 1.73 Copyright © 1997 Link Communications Inc. 1/18/97
157: Set Up Event Trigger
This command allows the user to assign a macro or command call when an event occurs in
order to get response or action to occur. These are useful for alarming, and interrogating events
that occur.
<157> eee ccc
Parameters:
- 157 is the default command name
- EEE is the Event Number (see table below)
- CCC is the command number to call when an event occurs
Default:
- All events are disabled
- When an event is programmed, the event is enabled
158: Recall Event Trigger Setting
This command allows the recall of what macro or command an event will jump to when a
change occurs.
<158> eee
Parameters:
- 158 is the default command name
- EEE is the Event Number
Default:
All events are disabled
159: Enable/Disable Event Trigger
This command allows the enable/disable control of the automatic event calling.
<159> eee 1 Enable an event
<159> eee 0 Disable an event
Parameters:
- 159 is the default command name
- EEE is the Event Number
Default:
All events are disabled