020: Program a Selected Timer
This command allows you to program the controller's timer system.
<020> xxx y
<020> xxx yy
<020> xxx yyy
Parameters:
- 020 is the default command name.
- XXX is the selected timer to be programmed
- YYYY is the value to be programmed into the timer (0 to 9999)
Message Start Delay Timer:
This timer sets the minimum delay between when a PTT goes active and when a voice message
will start. It is intended to give link systems time for all the links to come up before speaking.
It is not intended to set the delay between when a command is executed and when the response
is spoken (that is still in development).
- This timer is programmed in 10mS increments from 000-9999
Timer Number Definition Defaults
000 Message Start Delay Timer, Transmitter 1 500mS (050)
001 Message Start Delay Timer, Transmitter 2 "
002 Message Start Delay Timer, Autopatch "

Table of Contents