EasyManua.ls Logo

Link Communications RLC-CLUB - 000: Connect One Port to Another Port

Default Icon
329 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2-3
Version 1.73 Copyright © 1997 Link Communications Inc. 1/18/97
000: Connect one Port to another Port
This command allows you to connect one radio port to another radio port. It is also used to put
a port into "repeater mode", by connecting that port to itself. "Connecting a port" means that
the audio in and keying source from each port become the audio out and PTT source for the
other port. Connecting a port to itself makes the audio that comes in your repeater's receiver go
out your repeater's transmitter, making it into a repeater. If you connect two different ports
together, they will hear the activity from the other port.
<000> x y
Parameters:
- 000 is the default command name
- X is the first port to connect
- Y is the second port to connect
Default:
- Port 1 defaults as a repeater
- Port 2 defaults as a link
- Port 3 is the autopatch
Note:
If you want a one-way connection, where port A can monitor port B but port B can not
hear port A, use command 001.
Example 1:
Connect Port 1 to Port 2
000 1 2 D or unkey or <Enter>
Response:
Voice Response "1 Connect 2 On"
Example 2:
Want port 2 as a repeater port
000 2 2 D or unkey or <Enter>
Response:
Voice Response "2 Connect 2 On"

Table of Contents

Related product manuals