000: Connect one Port to another Port
This command allows you to connect one radio port to another radio port. It is also used to put
a port into "repeater mode", by connecting that port to itself. "Connecting a port" means that
the audio in and keying source from each port become the audio out and PTT source for the
other port. Connecting a port to itself makes the audio that comes in your repeater's receiver go
out your repeater's transmitter, making it into a repeater. If you connect two different ports
together, they will hear the activity from the other port.
<000> x y
Parameters:
- 000 is the default command name
- X is the first port to connect
- Y is the second port to connect
Default:
- Port 1 defaults as a repeater
- Port 2 defaults as a link
- Port 3 is the autopatch
Note:
If you want a one-way connection, where port A can monitor port B but port B can not
hear port A, use command 001.
Example 1:
Connect Port 1 to Port 2
000 1 2 D or unkey or <Enter>
Response:
Voice Response "1 Connect 2 On"
Example 2:
Want port 2 as a repeater port
000 2 2 D or unkey or <Enter>
Response:
Voice Response "2 Connect 2 On"

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Link Communications RLC-CLUB and is the answer not in the manual?

Link Communications RLC-CLUB Specifications

General IconGeneral
BrandLink Communications
ModelRLC-CLUB
CategoryController
LanguageEnglish

Related product manuals