9-4
Version 1.73 Copyright © 1997 Link Communications Inc. 1/18/97
071: Configure a Link for Preaccess
This command sets up a link to use the preaccess system. Links that are configured for
preaccess will ignore any DTMF tones that are not preceeded by Z..Z where Z..Z is the site
access code you specify below. This allows commands to be sent down a linking system
without every controller along the way trying to execute them, sending error messages, etc. To
execute a command from such a link port, key up, enter Z..Z and the command. It will be
executed when you unkey or press 'D'
<071> p y
z..z
Parameters:
- 071 is the default command name.
- P is the port to set up as a preaccess link
- Y is 0 for no dial tone when accessed, 1 for dial tone
- Z..Z is the site access code. Typical site access codes are "#11", "#75", "#99", etc.,
that is a '#' followed by two decimal digits. The controller will allow any
preaccess code from 1 to 6 digits long with any of the 16 DTMF digits in
it, although you may have to change your force-execution digit
temporarily (see command 078) while you execute this command to use
the force-execution digit as part of the access code.