14-19
Version 1.73 Copyright © 1997 Link Communications Inc. 1/18/97
149: Recall Band, Frequency& Offset for RBI-1 or RLC-ICM
This command allows you recall the current band, frequency and offset settings of the radio
connected to the Doug Hall RBI-1. The format of the voice response is given below. If you
want information about power, PL, etc., see the next command: Command 150.
<149>
Parameters:
- 149 is the default command name.
Voice Response:
XXX.YYY The frequency in MHz. Determined by both the band (set with Command
141) and the frequency within the band (set with Command 142).
O The offset as indicated below:
"minus" minus offset
"s" simplex
"plus" plus offset
"minus 20" minus 20 MHz offset (1200 radios only)
150: Recall All RBI-1 or RLC-ICM Settings
This command allows you recall all of the current settings for the RBI-1. The format of the
voice response is given below.
<150>
Parameters:
- 150 is the default command name.
Voice Response:
XXX.YYY The frequency in MHz. Determined by both the band (set with Command
141) and the frequency within the band (set with Command 142).
O The offset as indicated below:
"minus" minus offset
"s" simplex
"plus" plus offset
"minus 20" minus 20 MHz offset (1200 radios only)
"power XXXX" power setting is low/moderate/high"
"PL XX.X Hertz" PL (CTCSS) frequency is XX.X hertz
"PL TX On/Off" PL encoder is on/off, "PL RX On/Off", PL decoder is on/off

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Link Communications RLC-CLUB and is the answer not in the manual?

Link Communications RLC-CLUB Specifications

General IconGeneral
BrandLink Communications
ModelRLC-CLUB
CategoryController
LanguageEnglish

Related product manuals