Page #198 background image
13-12
Version 1.73 Copyright © 1997 Link Communications Inc. 1/18/97
121: Set Nuisance Numbers Table Slot
This command allows you to set one of the slots in the nuisance number table. For a
description of this table and how to use it, see the explaination of the dialing tables before
Command 110.
<121> sss d..d
Parameters:
- 121 is the default command name.
- SSS is the slot number (000..099)
- D..D is the whole number to be blocked (do include the last four digits of the phone
number). The '#' digit is a wildcard that matches any digit.
122: Recall Nuisance Numbers Table Slot
This command allows you to recall the contents of one of the slots in the nuisance number
table. For a description of this table and how to use it, see the explaination of the dialing tables
before Command 110.
<122> ss
Parameters:
- 122 is the default command name.
- SS is the slot number (00..99)
- D..D is the whole number to be blocked (do include the last four digits of the phone
number). The '#' digit is a wildcard that matches any digit.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Link Communications RLC-CLUB and is the answer not in the manual?

Link Communications RLC-CLUB Specifications

General IconGeneral
BrandLink Communications
ModelRLC-CLUB
CategoryController
LanguageEnglish

Related product manuals