009: Recall Entire Controller's Audio Crosspoint
This command allows you check the audio crosspoint conditions on all radio ports on the
controller. This command will check the connected conditions and both show the crosspoint
map on the RS-232 serial port, and will speak the conditions out the port that DTMF requested
the conditions.
<009>
Parameters:
- 009 is the default command name.
Default:
- None
Voice Response:
The voice response will only speak if a receiver is connected on the selected port. If a
receiver is connected to a port's transmitter, the controller will speak "RX connect TX" where
RX and TX are the port numbers of the receiver and transmitter, respectively.
Voice Format:
1 Connect <TX1> <TX2> <TX3>
2 Connect <TX1> <TX2> <TX3>
3 Connect <TX1> <TX2> <TX3>
Serial Format:
TX
1 2 3
1 . . .
RX 2 . . .
3 . . .