12-5
Version 1.73 Copyright © 1997 Link Communications Inc. 1/18/97
092: Enable/Disable Input Line Alarm
This command allows you to turn on input line alarms that will occur whenever an input line
goes high or low. When the alarm occurs, it will execute the input line high or low macro.
Note that these are the same macros that get executed by Command 091 whenever the input
line is read. The high and low alarms can be enabled or disabled separately.
<092> l a c
Parameters:
- 092 is the default command name.
- L is the input line number (1..4)
- A is 1 for the high alarm, 0 for the low alarm
- C is 1 to enable the alarm, 0 to disable it
Note:
There is currently no command recall whether the input line alarm is turned on or off.