9-7
Version 1.73 Copyright © 1997 Link Communications Inc. 1/18/97
076: Recall Stop Access Conditions
This command allows you to recall the conditions that will stop access on a port. See
Command 075 for descriptions of the conditions.
<076> p
Parameters:
- 076 is the default command name.
- P is the port for which to recall the stop access conditions (1..2)
077: Isolate a Port from the Rest of the System
This command breaks the audio and ptt links between the specified port and all other ports in
the system until the preaccess timer (which it starts) runs out. It temporarily overrides but does
not change the crosspoint connections you may have set with Commands 000 and 001. It is
useful for isolating a port while you enter local control commands without the tones going
down any connected links. It is usually called from the preaccess macro of a port configured as
a repeater. This macro is usually named '*', the local control key.
<077> p
Parameters:
- 077 is the default command name.
- P is the port for which to allow access (1..2)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Link Communications RLC-CLUB and is the answer not in the manual?

Link Communications RLC-CLUB Specifications

General IconGeneral
BrandLink Communications
ModelRLC-CLUB
CategoryController
LanguageEnglish

Related product manuals