Malfunctions in driving mode
8.5 Emergency operation and breakdown assistance
8 - 38 3 302 819 en Operating manual
GMK3060
13.12.2018
Inflating the tyres The maximum operation pressure of the compressed air system of 10 bar
(145 psi) can only be reached with the engine running.
• Start the engine; à p. 4 - 12.
• Fasten the tyre connection (1) to the tyre valve.
• Press the button on the tyre connection and
inflate the tyre.
• Disconnect the tyre connection (1) from the tyre
valve.
Remove the
filling hose
Before driving, you must remove the tyre filling hose from the tyre inflator
connection.
• Remove the connection (1) from the filler
connection (2).
• Close the filler connection and the connection
with the caps (3) and (4).
• Stow the filling hose away.
• Drive to a service station or repair shop and
adjust the tyre pressure.
S
Risk of damage to the compressed air system!
Always close the filler connection with the cap.
This prevents damage to the compressed air system and contamination of it.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc GROVE GMK3060 and is the answer not in the manual?

Manitowoc GROVE GMK3060 Specifications

General IconGeneral
BrandManitowoc
ModelGROVE GMK3060
CategoryConstruction Equipment
LanguageEnglish

Related product manuals