Malfunctions during crane operation
14.7 Hydraulic emergency operation as per DGUV
Operating manual 3 302 819 en 14 - 61
GMK3060
13.12.2018
14.7.4 For self-supply – connecting/disconnecting hoses
(A) – Establishing the connection
The required hose is supplied with the crane.
• Connect connections (1) and (3) using the
hose (2).
(B) – Disconnecting the connection
• Remove the hose from the connections (1)
and (3).
• Close the hose and the connections with the
caps.
S
Risk of damage to the hose!
Lay the hose in such a manner that it can be moved freely in order to prevent it
being crushed or torn or getting caught during the subsequent crane operations.