Malfunctions in driving mode
8.7 Fuses on the carrier
Operating manual 3 302 819 en 8 - 43
GMK3060
13.12.2018
8.7 Fuses on the carrier
The fuses are divided into groups and are at various points on the carrier:
– In the driver's cab,
– In the battery box.
Notes on
changing fuses
The positions of the fuses, their designations and which functions are protected
by the respective fuses are shown in the following sections.
• Switch off the ignition whenever a fuse has to be replaced.
S
Risk of damage if the ignition is switched on!
Switch off the ignition whenever a fuse has to be replaced. This prevents the new
fuse being blown immediately by the increased starting current after being
installed.
S
Risk of damage by overloading!
Replace blown fuses only with new fuses of the same amperage. This prevents
parts being overloaded and damaged or the fuse being immediately blown again.
Notify
Manitowoc Crane Care if a fuse with the same amperage blows again when
the ignition is switched on.
S
Risk of fire!
Never repair a blown fuse with other electrically conductive materials.