Malfunctions during crane operation
14.6 Hydraulic emergency operation with the hand pump
14 - 56 3 302 819 en Operating manual
GMK3060
13.12.2018
14.6.5 After emergency activation
You must restore the truck crane to its original state after finishing emergency
activation.
After each emergency activation
• Disconnect the hose connection; à p. 14 - 52.
• Remove the lever from the hand pump.
Also after lifting/lowering
• Switch off the continuous operation; à p. 14 - 55.