EasyManua.ls Logo

Manitowoc GROVE GMK3060

Manitowoc GROVE GMK3060
906 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Malfunctions during crane operation
14.3 Warning and error messages
Operating manual 3 302 819 en 14 - 7
GMK3060
13.12.2018
Emergency stop switch actuated
à Resetting the emergency stop switch, p. 4 - 20
Unknown telescoping
RCL and CCS measure different values for the current telescoping – an RCL
shutdown occurs.
You can enter the current telescope status if necessary;
à p. 14 - 41.
In an emergency, you can override the RCL to bring the truck crane into a safe
state;
à RCL override – version A, p. 11 - 67.
Vehicle brake
Stop the truck crane immediately and check the pressure in the brake circuits;
à p. 5 - 9.
Parking brake released
Information – the parking brake was released from the crane cab.
This section does not include all messages. Symbols described for driving may
also be displayed;
à Warning messages on the CCS display, p. 8 - 10.

Table of Contents