Malfunctions during crane operation
14.3 Warning and error messages
Operating manual 3 302 819 en 14 - 7
GMK3060
13.12.2018
Emergency stop switch actuated
à Resetting the emergency stop switch, p. 4 - 20
Unknown telescoping
RCL and CCS measure different values for the current telescoping – an RCL
shutdown occurs.
You can enter the current telescope status if necessary;
à p. 14 - 41.
In an emergency, you can override the RCL to bring the truck crane into a safe
state;
à RCL override – version A, p. 11 - 67.
Vehicle brake
• Stop the truck crane immediately and check the pressure in the brake circuits;
à p. 5 - 9.
Parking brake released
Information – the parking brake was released from the crane cab.
This section does not include all messages. Symbols described for driving may
also be displayed;
à Warning messages on the CCS display, p. 8 - 10.