Malfunctions during crane operation
14.5 Emergency operations and programs
14 - 40 3 302 819 en Operating manual
GMK3060
13.12.2018
Locking points for the telescopic sections
The telescopic section must not be set down for locking or unlocking.
The cutout (1) must be clear. You must therefore extend the telescoping cylinder
35 mm (0.11 ft) further than with a return run.
The following table shows the extended length for locking and unlocking the
telescopic sections.
12
Table for locking/unlocking the telescopic sections
Telescopic
section
Locking point at fixed
length
Extended length of
telescoping cylinder
in % in mm (in ft)
Telescopic
section
I
0
47
47,100
5
3,436
7,207
(0.02)
(11.27)
(23.64)
Telescopic
section
II
0
49
100
347
3,780
7,359
(1.14)
(12.40)
(24.14)
Telescopic
section
III
0
51
100
666
4,100
7,359
(2.19)
(13.45)
(24.14)
Telescopic
section
IV
0
53
100
938
4,370
7,359
(3.08)
(14.34)
(24.14)
Telescopic
section
V
0
55
100
1,189
4,621
7,364
(3.90)
(15.16)
(24.16)