9 Description of the object dictionary
Object name Encoder Configuration
Object Code VARIABLE
Data type UNSIGNED32
Savable yes, category: tuning
Access read / write
PDO mapping no
Allowed values
Preset value 00000000
h
Firmware version FIR-v1426
Change history
Firmware version FIR-v1614: "Savable" entry changed from "yes,
category: application" to "yes, category: tuning".
Description
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
TYPE
TYPE
Defines the type of encoder. For a differential encoder, the bit must have the value "0". For a single-
ended encoder, the bit must be set to "1".
205Ah Encoder Boot Value
Function
Tip
This object only has a function when using an absolute encoder. If an absolute encoder is not used,
the value is always 0.
The initial encoder position when switching on the controller (in user-defined units) can be read from this
object.
Object description
Index 205A
h
Object name Encoder Boot Value
Object Code VARIABLE
Data type UNSIGNED32
Savable no
Access read only
PDO mapping no
Allowed values
Preset value 00000000
h
Firmware version FIR-v1446
Version: 2.0.1 / FIR-v1650 141