EasyManua.ls Logo

NANOTEC PD4-C - 3320 H Read Analogue Input

Default Icon
256 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9 Description of the object dictionary
Name Output Control #4
Data type UNSIGNED16
Access read / write
PDO mapping TX-PDO
Allowed values
Preset value 0092
h
Subindex 05
h
Name Output Control #5
Data type UNSIGNED16
Access read / write
PDO mapping TX-PDO
Allowed values
Preset value 0093
h
3320h Read Analogue Input
Function
Displays the instantaneous values of the analog inputs in user-defined units.
Object description
Index 3320
h
Object name Read Analogue Input
Object Code ARRAY
Data type INTEGER32
Savable no
Firmware version FIR-v1426
Change history
Value description
Subindex 00
h
Name Number Of Analogue Inputs
Data type UNSIGNED8
Access read only
PDO mapping no
Allowed values
Preset value 02
h
Subindex 01
h
Name Analogue Input 1
Data type INTEGER32
Access read only
Version: 2.0.1 / FIR-v1650 189