9 Description of the object dictionary
Number Description
10005
h
Folder not found
10006
h
Invalid file name/folder name
10008
h
Access of file not possible
10009
h
File/directory object is invalid
1000A
h
Storage medium is read-only
1000B
h
Drive number is invalid
1000C
h
Working range of the drive is invalid
1000D
h
No valid file system on the drive
1000E
h
Creation of the file system failed
1000F
h
Access not possible within the required time
10010
h
Access was rejected
230Fh Uptime Seconds
Function
This object contains the operating hours in seconds since the last time the controller was started.
Note
This object is not stored; counting begins with "0" again after switching on.
Object description
Index 230F
h
Object name Uptime Seconds
Object Code VARIABLE
Data type UNSIGNED32
Savable no
Access read only
PDO mapping TX-PDO
Allowed values
Preset value 00000000
h
Firmware version FIR-v1436
Change history
2310h NanoJ Input Data Selection
Function
Describes the object dictionary entries that are copied to the PDO mapping input of the NanoJ program.
Object description
Index 2310
h
Object name NanoJ Input Data Selection
Object Code ARRAY
Version: 2.0.1 / FIR-v1650 153