EasyManua.ls Logo

NEC Aspila Topaz - 14-07: Trunk Access Map Setup

NEC Aspila Topaz
390 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
93
Programming Manual
Program 14: Trunk Basic Setup
14-07: Trunk Access Map Setup
SA
SB
IN
Description
Use Program 14-07 : Trunk Access Map Setup to set up the Trunk Access Maps. This sets an extension’s access
options for trunks. For example, an extension can only place outgoing calls on trunks to which it has outgoing
access. There are 51 Access Maps with all 51 trunk ports programmed in Map 1 with full access.
An extension can use one of the maps you set up in this program. Use Program 15-06 to assign Trunk Access Maps
to extensions. Each trunk can have one of eight access options for each Access Map.
Input Data
Access Map Number
1-51
Trunk Port Number Input Data
1-51
0 : No Access
1 : Outgoing Access only
2 : Incoming Access only
3 : Access when trunk on Hold
4 : Outgoing Access and Access when trunk on Hold
5 : Incoming Access and Access when trunk on Hold
6 : Incoming and Outgoing Access
7 : Incoming Access, Outgoing Access and Access when trunk on Hold
Default
Access Map Number Trunk Port Number Default
17
27
::
1
51 7
10
20
::
2
51 0
10
20
::
:
51 0
10
20
::
51
51 0
Conditions
None
Feature Cross Reference