Program 90: Maintenance Program
90-10: System Alarm Setup
SA
SB
IN
Description
Use Program 90-10 : System Alarm Setup to assign a status to system alarms. You can designate an alarm as
Major or Minor. This program also assigns whether or not the alarm is displayed to a key telephone and whether or
not the alarm information is reported to the pre-defined destination.
Input Data
Alarm Number
001-100
Prog.No. Item Input Data
Related
Program
90-10-01 Alarm Type
0 : Not set
1 : Major Alarm
2 : Minor Alarm
90-10-02 Report
0 : Not report (No Auto-Dial)
1 : Report (Auto-Dial)
Default
Alarm Type Report Note Is Used To Advise of…….. Action
1 2(MIN) 0 Board Initialization
Error
Initialization Failure or the
PCB is defective
Remove and reinstall the
PCB.
2 2(MIN) 0 Board Installation
Error
PCB was unplugged without
using the proper procedure.
Check the PCB installation.
3 2(MIN) 0 Communication
Error between
Board and EXIFU
PCB communication failure
has occurred.
Remove and reinstall the
PCB. If RECover message is
received in the alarm report,
the PCB is good. If not,
replace with a new PCB.
4 2(MIN) 0 PCB Program
Download Error
Download may have failed
because the PCB is
blocked(disabled) or the sub
-program does not exist on
the system flash card.
After unblocking the PCB, if
RECover message is
received in the alarm report,
it is corrected. If not, then
replace the system flash
card.
50 0-Not Used- - -
6 0 0 Blocking (No
default setting)
Failure may have occurred
because:
• Terminal blocking
detected.
• Terminal is unplugged.
• Wire is disconnected.
• 308 card is defective.
Check the terminal wiring
and reconnect properly.
Then unplug and plug in the
PCB. If RECover message is
received in the alarm report,
it is correct. If not, replace
the PCB and/or
terminal.
7 1(MAJ) 0 -Not Used- - -
8 1(MAJ) 0 RAM Backup
Battery Error
RAM backup battery on the
308M PCB is unplugged or
defective.
Check the battery connector.
If it is connected correctly,
then replace the battery.
90 0-Not Used- - -