357
Programming Manual
Program 90: Maintenance Program
90-06: Trunk Contro
IN
SA
SB
Description
Use Program 90-06 : Trunk Control is used for the trunk maintenance. Busy Out lets you block a PCB from
placing outgoing calls. Once busied out, none of the ports on the PCB can be used for new calls. Existing calls,
however, are not torn down.
Input Data
Trunk Port Number
1-51
Menu Number
1 : Set Busy Out
2 : Reset/Release Busy Out
Conditions
None
Feature Cross Reference
None
Telephone Programming Instructions
To enter data for Program 90-06 (Trunk Control):
1. Enter the programming mode.
2. Enter 90 05
3. Enter the number of the item you want to program.
4. Select the Menu number to be programmed by pressing the FLASH or the VOLUME▲ or VOLUME▼ keys.
5. Enter data for the item you selected + HOLD.
6. Enter data for the next item in the program.
OR
Press DC once to enter a new item number.
OR
Press DC until you’ve exited that series’s programming section.
90-06-01 Trunk1
Menu
90-06-xx Trunkx
xxxxx