Description
Use Program 81-07 : CODEC Filter Setup for Analogue Trunk Ports to define the CODEC (QSLAC) Filter for
each analogue trunk port(308M/308ME).
Input Data
Trunk Port Number
1-51
CODEC Filter Type Default
Related
Program
0 : No filter
1 : 0 dB Loss
2 : 4 dB Loss
3 : 8 dB Loss
4 : Specified Data
2
81-09
Conditions
None
Feature Cross Reference
None
Telephone Programming Instructions
To enter data for Program 81-07 (CODEC Filter Setup for Analogue Trunk Ports):
1. Enter the programming mode.
2. Enter 81 07
3. Enter the number of the item you want to program.
4. Select the Trunk port number to be programmed by pressing the FLASH or the VOLUME or VOLUME
keys.
5. Enter data for the item you selected + HOLD.
6. Enter data for the next item in the program.
OR
Press DC once to enter a new item number.
OR
Press DC until you’ve exited that series’s programming section.
81-07-01 Trunk1
CODEC Filter 1