192
Programming Manual
Program 22: Incoming Call Setup
22-03: Trunk Ring Tone Setup
IN
SA
SB
COP
Description
Use Program 22-03 : Trunk Ring Tone Setup to select the ring tone range for the trunk. The trunk uses a ring tone
within the range selected when it rings an extension. There are three ring tones available.
Input Data
Trunk Port Number
1-51
Ring Tone Pattern Default Description
Related
Program
0-2
(Ring Tone pattern 1-3)
0
Use this program to select the ring tone range
for the trunk. The trunk uses a ring tone within
the range selected when it rings an extension.
There are three ring tones available.
15-02
Incoming Signal Frequency Pattern Frequency Modulation
0: Tone Pattern 1 600/450/16Hz FM
1: Tone Pattern 2 450/16Hz AM
2: Tone Pattern 3 600Hz
Conditions
None
Feature Cross Reference
Selectable Ring Tones