Program 14: Trunk Basic Setup
14-01: Basic Trunk Data Setup
Programming Manual
IN
SA
SB
COP
Y
Description
Use Program 14-01 : Basic Trunk Data Setup to set the basic options for each trunk port. Refer to the chart below
for a description of each option, its range and default setting.
Input Data
Trunk Port Number
1-51
Prog. No. Item Input data Default Related Program
14-01-01
Trunk Name
Set the names for trunks. The trunk
name displays at display keysets
for incoming and outgoing calls.
Up to 12 Characters Refer
below
14-01-02
Transmit CODEC Gain Type
Use this option to select the
CODEC gain for the trunk.
The option sets the amount of gain
(signal amplification) for the trunk
you are programming.
1-63
(-15.5dB - +15.5dB in
0.5dB intervals)
32
(0 dB)
14-01-03
Receive CODEC Gain Type
Use this option to select the
CODEC gain for the trunk.
The option sets the amount of gain
(signal amplification) for the trunk
you are programming.
1-63
(-15.5dB - +15.5dB in
0.5dB intervals)
32
(0 dB)
14-01-04
Transmit Gain Level for
Conference and Transfer Calls
Use this option to select the
CODEC gain type used by the
trunk when it is part of an
Unsupervised Conference.
1-63
(-15.5dB - +15.5dB in
0.5dB intervals)
22
(-5dB)
14-01-05
Receive Gain Level for
Conference and Transfer Calls
Use this option to select the
CODEC gain type used by the
trunk when it is part of an
Unsupervised Conference.
1-63
(-15.5dB - +15.5dB in
0.5dB intervals)
22
(-5dB)
14-01-06
SMDR Print Out
Use this option to have the system
include/exclude the trunk you are
programming form the SMDR
printout. See Program 35-01 and
35-02 for SMDR printout options.
0 : No Printout
1 : Printout
1
14-01-07
Outgoing Calls
Use this option to allow/prevent
outgoing calls on the trunk you are
programming.
0 : Prevented
1 : Allowed
1