338
Programming Manual
Program 81: Basic Hardware Setup for Trunk
81-09:
Analogue Trunk CODEC Filter Setup
 
IN
SA
SB
Description
Use Program 81-09 : Analogue Trunk CODEC Filter Setup to define the CODEC (QSLAC) Filter data for each
analogue Trunk Interface(308M/308E card). This setting is applied when CODEC filter type4 (Specified Data) is set
in PRG81-07.
Input Data
Prog. No. Item Input Data
Default
81-09-01
B1 Filter Setup(1) 0-255
74
81-09-02
B1 Filter Setup(2) 0-255
226
81-09-03
B1 Filter Setup(3) 0-255
171
81-09-04
B1 Filter Setup(4) 0-255
42
81-09-05
B1 Filter Setup(5) 0-255
21
81-09-06
B1 Filter Setup(6) 0-255
33
81-09-07
B1 Filter Setup(7) 0-255
234
81-09-08
B1 Filter Setup(8) 0-255
26
81-09-09
B1 Filter Setup(9) 0-255
51
81-09-10
B1 Filter Setup(10) 0-255
82
81-09-11
B1 Filter Setup(11) 0-255
99
81-09-12
B1 Filter Setup(12) 0-255
47
81-09-13
B1 Filter Setup(13) 0-255
162
81-09-14
B1 Filter Setup(14) 0-255
224
81-09-15
B2 Filter Setup(1) 0-255
162
81-09-16
B2 Filter Setup(2) 0-255
192