173
Programming Manual
Program 21: Outgoing Call Setup
21-06: Toll Restriction Table Data Setup
SA
SB
IN
Description
Use Program 21-06 : Toll Restriction Table Data Setup to set the system’s Toll Restriction data.
Dial 1-9, 0, *, # can be entered in each table.
Input Data
Prog. No. Item Ta b le Input Data Default Description
21-06-01
International Call
restriction table
1-10
Dial (Up to
4 digits)
No setting This option lets you program the
Restrict Table for international calls.
The system has 10 International Call
Restrict Tables. Each entry can be up
to four digits long.
21-06-02
International Call
permit code table
1-20
Dial (Up to
6 digits)
No setting This option lets you program the
Permit Table for international calls.
The system has 20 International Call
Permit Table. Each entry can be up to
six digits long, using.
21-06-03
Maximum Number
of Digits Table
Assignment
1-4 4-30
Table 1-4
= 30 digits
This option selects the maximum
number of digits allowed in outgoing
calls for each table.
21-06-04
Common permit
code table
1-10
Dial (Up to
4 digits)
No setting This option lets you program the
Common Permit Code Table. This
table contains up to 10 codes you
commonly allow users to dial
21-06-05
Common restriction
table
1-10
Dial (Up to
12 digits)
No setting This option lets you program the
Common Restrict Code Table. This
table contains up to 10 codes you
commonly prevent users from
dialing.
21-06-06
Permit code table
1-4
(table)
1-200
(entry)
Dial (Up to
12 digits)
No setting This option lets you program the
Permit Code Tables. If the system
has Toll Restriction enabled, users
can dial numbers only if permitted by
these tables and the Common Permit
Table (21-06-04). There are four
Permit Code Tables, with up to 200
entries in each table. The system
permits calls exactly as you enter the
code.
21-06-07
Restriction table
1-4
(table)
1-60
entr
Dial (Up to
12 digits)
No setting This option lets you program the
Restrict Code Tables. If the system
has Toll Restriction enabled, users
cannot dial numbers listed in these
tables. There are four Restrict Code
Tables, with up to 200 entries in each
table. The system restricts calls
exactly as you enter the code.