Programming Manual
Program 11: System Numberin
g
11-06:
A
CI Extension Numberin
g
IN
SA
SB
Description
Use Program 11-06 : ACI Extension Numbering to define the ACI extension numbers. The extension number can
be up to four digits long. The first/second digit(s) of the number should be assigned in Program 11-01.
ACI Port Number
1-6
ACI Extension
Number
Description Related Program
Dial (up to 4 digits)
The extension number cannot be duplicated in Programs 11-
02, 11-04, 11-06 and 11-07.
10-03
Default
ACI Port Number 1-6: No setting (ACI Extension Number)
Conditions
None
Feature Cross Reference
Analogue Communication Interface(ACI)
Flexible Station Numbering
Telephone Programming Instructions
To enter data for Program 11-06 (ACI Extension Numbering):
1. Enter the programming mode.
2. Enter 11 06
3. Enter the number of the item you want to program.
4. Select the ACI Port number to be programmed by pressing the FLASH or the VOLUME or VOLUME keys.
5. Enter data for the item you selected + HOLD.
6. Enter data for the next item in the program.
OR
Press DC once to enter a new item number.
OR
Press DC until you’ve exited that series’s programming section.
11-06-
01ACIPort1
11-06-xxACIPortx
xxxxx