Programming Manual
Program 25: DID/DISA Setup
25-05: DID/DISA Error Message Assignmen
t
SA
SB
IN
Description
Use Program 25-05 : DID/DISA Error Message Assignment to assign the VRS message number to be used as the
Automated Attendant error message. For each DID/DISA trunk that the VRS will answer, enter the VRS message
(1-48) the outside caller hears if they dial incorrectly. If you enter 0 (i.e., no error message), the call reroutes
according to Program 25-03 and 25-04.
For each trunk, you make a separate entry for each Night Service mode.
Input Data
Trunk Port Number
1-51
Day/Night Mode VRS Message Number Default Related Program
1-8
0-48 (0 : No setting) 0
Conditions
None
Feature Cross Reference
Direct Inward System Access (DISA)
Telephone Programming Instructions
To enter data for Program 25-05(DID/DISA Error Message Assignment):
1. Enter the programming mode.
2. Enter 25 05
3. Enter the number of the item you want to program.
4. Select the Trunk port number to be programmed by pressing the FLASH or the VOLUME or VOLUME
keys.
5. Enter data for the item you selected + HOLD.
6. Enter data for the next item in the program.
OR
Press DC once to enter a new item number.
OR
Press DC until you’ve exited that series’s programming section.
25-05-01TrkPrt1
Mode1 MSG No=0
25-05-xxTrkPrtxx
xxxxx