Use Program 81-01 : Analogue Trunk Initial Data Setup to define the various basic timers for the Trunk
Interface of 308M/308ME cards.
Input Data
Prog. No. Item Input Data
Default
81-01-01
Companding method type
0 : μ-law
1 : A-law
1(A-law)
81-01-02
Loop Current Detection Time
1-255(8-2040ms)
75(600ms)
81-01-03
Clear Signal (Open Loop)Detection Time
1-255(8-2040ms) 37(296ms)
81-01-04
Ring Signal Detection Min. Time
1-255(8-2040ms) 13(104ms)
81-01-05
Single Ringing Detection Min. Time
0-255(0,8-2040ms) 82(656ms)
81-01-06
Double Ringing Detection Min. Off Time 0-255 (0,8-2040mS) 13 (104ms)
81-01-07
Double Ringing Detection Max. Off Time 0-255 (0,8-2040mS) 50 (400ms)
81-01-08
Ringing Signal Not Detection Minimum 1-255 (8-2040mS) 88 (704ms)
81-01-09
Time Ringing Signal Stop Detection Time
1-255 (64-16320mS)
47(3080ms)
81-01-10
Continuous Ringing Minimum Time
0-255 (0,8-2040mS)
38(304ms)
81-01-11
Continuous Ringing Maximum Time
0-255 (0,8-2040mS)
88(704ms)
81-01-12
AC Impedance Timer 1-255 (64-16320mS) 4 (256ms)
81-01-13
Grounding Time 1-255 (16-4080mS) 9 (144ms)
81-01-14
Flash (Hooking 1)
This sets the flash (Hooking 1) duration for
analogue trunk calls. See Program 14-02-04.
1-255 (16-4080mS) 50 (800ms)
81-01-15
Flash (Hooking 2)
This sets the flash (Hooking 2) duration for
analogue trunk calls. See Program 14-02-04.
1-255 (16-4080mS)
156(2496ms)
81-01-16
Pause Time
1-255(64-16320mS) 47(3008ms)
81-01-17
PFT Idle Detection Time
1-255(64-16320mS) 47(3008ms)
81-01-18
Grounding Start Time 1-255 (8-2040mS) 6 (48ms)
81-01-19
Grounding Start Give-up Time 1-255 (64-16320mS) 47 (3008ms)
81-01-20
Loop Reverse Detect Min. Time 1-255 (8-2040mS) 13 (104ms)
81-01-21
Loop Reverse Detect Max. Time 1-255 (8-2040mS) 107 (856ms)
81-01-22
Loop Disconnect Detect Min. Time
1-255 (8-2040mS)
63(504ms)
81-01-23
Loop Disconnect Detect Max. Time 1-255 (8-2040mS)
87(696ms)
81-01-24
On Hook Normal Detect Time
1-255 (8-2040mS)
3(24ms)
81-01-25
On Hook Reverse Detect Time 1-255 (8-2040mS) 2 (16ms)
81-01-26
On Hook Disconnect Detect Time 1-255 (16-4080mS) 188 (3008ms)